S.R.E 142

CABINET

X-ray system complies without the cabinet. The cabinet has to be in workplace area of customer with the strictest regulations for fully shielded radiation devices.

MANIPULATOR

The inspection positions are obtained by the movement of the complete X-ray system (X-ray tube and detector) by a C-arm. Six axes of movement guaranties that all inspection angles can be easily achieved. All motors are controlled by CNC for high speed movement and accurate positioning.

The inspection programs are made by teach-in utilities which allow for the storage unlimited programs. Positioning is made by joysticks. X-ray kV and mA variation is also automatically controlled by RS-232 serial line. For small castings removable table can be used.

X-RAY/TV

The SRE 142 could be equipped with different combinations of generators/tubes, different power are available, from 160 kV up to 225 kV. It could be equipped with amorphous silicon digital flat panel detector.

CONTROL CONSOLE

A computer installed with BOSELLO BHT software controls all functions of the equipment, all axes movements and diagnostics. The inspection programs are made by teach-in software which allows for the storage of several programs. The personal computer can be connected to the peripheral devices. An Ethernet port is also available for connection with a local area network (LAN).

An operator panel with the main functions, pushbuttons and joysticks for axes movement is located in an ergonomic air console. There is also located the screens (monitors). A 19” VGA monitor for user interface, programming, image processing and diagnostic functions.